"Tests of continuous sampling system and strategies of emission
「"Tests of continuous sampling system and strategies of emission 」於資料集「EPQSummary_EnvironmentalMonitoringAndTesting」由單位「行政院環境保護署」的陳先生所提供,聯繫電話是02-2311-7722#2386,最近更新時間為:2023-07-30 01:01:45。 欄位Project Title的內容是"Tests of continuous sampling system and strategies of emission control for a large-scale MWI in Kaohsiung City (2015)" , 欄位Project Subject的內容是"In general, concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) measured in flue gas of municipal wastes incinerators (MWIs) vary significantly with waste component, combustion condition, operation stages and air pollution control devices equipped. Manual or short-time stack sampling process for dioxin-like congeners is the standard sampling method adopted by the Taiwan EPA (Method No. A807). However, it is difficult to include the dioxin emitted during unstable conditions, such as start-up process and abnormal condition. NCU-CS3 is a continuous stack sampling system developed by National Central University, Taiwan. In parallel with the Taiwan EPA standard sampling method (Method No. A807.75C), NCU-CS3 was used to monitor the emission of PCDD/Fs from a large-scale MWI in Kaohsiung city, Taiwan, including the periods of start-up and normal operation. Due to the unstable operating condition, the dioxin emission during start-up procedure (48 hours) could reach the peak of 50.8 ng I-TEQ/Nm3 before gradually decreasing in the following weeks. To reduce PCDD/F concentration in flue gas of the MWI, three measures have been carried out such as (1) reducing CO concentration, (2) removing the fly ash accumulated on the pipe and (3) alkali injection before the start-up procedure. The results obtained from the second measurements indicated the PCDD/Fs concentrations in flue gas measured by both NCU-CS3 and NIEA A807.75C were significantly lower than the first measurement and typically lower than 2.04 ng I-TEQ/Nm3. After 2 days’ operation, the PCDD/F emissions measured by NCU-CS3 and NIEA A807.75C were lower than the emission limit (0.1 ng I-TEQ/Nm3). In addition, the dioxin emissions of 168-hour continuous sampling with NCU-CS3 and NIEA A807.75C ranged from 0.072 to 0.753 ng I-TEQ/Nm3 (0.201 ng I-TEQ/Nm3 in average). Among these measurements (n=7), only three measurements are lower than 0.1 ng I-TEQ/Nm3. At the same time, 70 samples were collected with the NIEA A807.75C method (ten NIEA A807.75C samples correspond to each NCU-CS3 measurement). The measured dioxin emission was 0.0609 ng I-TEQ/Nm3 in average (0.0012~0.3835 ng I-TEQ/Nm3), while 77% samples were lower than the emission limit. The average dioxin emission factors measured by using NCU-CS3 and NIEA A807.75C methods were 0.845 and 0.346 μg I-TEQ/ton-waste, respectively. The effects of relevant operating parameters on PCDD/Fs emission are also evaluated via NCU-CS3, and they include: (1) alkali injection: HCl emission at the stack was controlled at 19 ppm (normal operation) and 15 ppm; (2) activated carbon injection: 0.24, 0.34 (normal operation), 0.44 and 0.55 kg / ton waste. Eighteen NCU-CS3 sampling results indicate that dioxins measured in smokestack decreased with the increase of AC injection rate. The dioxin removal efficiency achieved with ACI + BF technology was between 98.7% and 99.4%. Results indicate that dioxin concentration in 2nd cartridge of the NCU-CS3 increases with increasing cooling temperature. At 50oC, 5.4% of total dioxin concentration penetrated into the 2nd stage XAD-2 cartridge. As the cooling temperature was lower than 20oC, penetration was lower than 1% and could be ignored. The NCU-CS3 system showed reliable results with 70-130% recoveries of surrogate standard, which meets the regulation of standard method (NIEA A807.75C). This new system is capable of automatic, continuous sampling over a long period of time (≤4 weeks), and can accurately measure the PCDD/Fs emitted from MWIs. The PCDD/F emission from the MWI investigated included the start-up procedure via the NCU-CS3 system was around 150 mg I-TEQ/yr. The PCDD/F emission contributed by the first and second start-up procedures were 52% and 7%, respectively. Hence, the PCDD/F emission cannot be accurately quantified by relying on the manual and sho..." , 欄位Project Year的內容是2015 , 欄位Organizer的內容是"Environmental Protection Bureau Kauhsiung City Government" , 欄位Executive Unit的內容是"中央大學" , 欄位Reporting download URL的內容是https://epq.epa.gov.tw/project/filedownload.aspx?fid=151189 , 欄位Publish Date的內容是20171101 。
Project Title
"Tests of continuous sampling system and strategies of emission control for a large-scale MWI in Kaohsiung City (2015)"
Project Subject
"In general, concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) measured in flue gas of municipal wastes incinerators (MWIs) vary significantly with waste component, combustion condition, operation stages and air pollution control devices equipped. Manual or short-time stack sampling process for dioxin-like congeners is the standard sampling method adopted by the Taiwan EPA (Method No. A807). However, it is difficult to include the dioxin emitted during unstable conditions, such as start-up process and abnormal condition. NCU-CS3 is a continuous stack sampling system developed by National Central University, Taiwan. In parallel with the Taiwan EPA standard sampling method (Method No. A807.75C), NCU-CS3 was used to monitor the emission of PCDD/Fs from a large-scale MWI in Kaohsiung city, Taiwan, including the periods of start-up and normal operation. Due to the unstable operating condition, the dioxin emission during start-up procedure (48 hours) could reach the peak of 50.8 ng I-TEQ/Nm3 before gradually decreasing in the following weeks. To reduce PCDD/F concentration in flue gas of the MWI, three measures have been carried out such as (1) reducing CO concentration, (2) removing the fly ash accumulated on the pipe and (3) alkali injection before the start-up procedure. The results obtained from the second measurements indicated the PCDD/Fs concentrations in flue gas measured by both NCU-CS3 and NIEA A807.75C were significantly lower than the first measurement and typically lower than 2.04 ng I-TEQ/Nm3. After 2 days’ operation, the PCDD/F emissions measured by NCU-CS3 and NIEA A807.75C were lower than the emission limit (0.1 ng I-TEQ/Nm3). In addition, the dioxin emissions of 168-hour continuous sampling with NCU-CS3 and NIEA A807.75C ranged from 0.072 to 0.753 ng I-TEQ/Nm3 (0.201 ng I-TEQ/Nm3 in average). Among these measurements (n=7), only three measurements are lower than 0.1 ng I-TEQ/Nm3. At the same time, 70 samples were collected with the NIEA A807.75C method (ten NIEA A807.75C samples correspond to each NCU-CS3 measurement). The measured dioxin emission was 0.0609 ng I-TEQ/Nm3 in average (0.0012~0.3835 ng I-TEQ/Nm3), while 77% samples were lower than the emission limit. The average dioxin emission factors measured by using NCU-CS3 and NIEA A807.75C methods were 0.845 and 0.346 μg I-TEQ/ton-waste, respectively. The effects of relevant operating parameters on PCDD/Fs emission are also evaluated via NCU-CS3, and they include: (1) alkali injection: HCl emission at the stack was controlled at 19 ppm (normal operation) and 15 ppm; (2) activated carbon injection: 0.24, 0.34 (normal operation), 0.44 and 0.55 kg / ton waste. Eighteen NCU-CS3 sampling results indicate that dioxins measured in smokestack decreased with the increase of AC injection rate. The dioxin removal efficiency achieved with ACI + BF technology was between 98.7% and 99.4%. Results indicate that dioxin concentration in 2nd cartridge of the NCU-CS3 increases with increasing cooling temperature. At 50oC, 5.4% of total dioxin concentration penetrated into the 2nd stage XAD-2 cartridge. As the cooling temperature was lower than 20oC, penetration was lower than 1% and could be ignored. The NCU-CS3 system showed reliable results with 70-130% recoveries of surrogate standard, which meets the regulation of standard method (NIEA A807.75C). This new system is capable of automatic, continuous sampling over a long period of time (≤4 weeks), and can accurately measure the PCDD/Fs emitted from MWIs. The PCDD/F emission from the MWI investigated included the start-up procedure via the NCU-CS3 system was around 150 mg I-TEQ/yr. The PCDD/F emission contributed by the first and second start-up procedures were 52% and 7%, respectively. Hence, the PCDD/F emission cannot be accurately quantified by relying on the manual and sho..."
Project Year
2015
Organizer
"Environmental Protection Bureau Kauhsiung City Government"
Executive Unit
"中央大學"
Reporting download URL
Publish Date
20171101
「"Tests of continuous sampling system and strategies of emission 」所屬的資料集:「EPQSummary_EnvironmentalMonitoringAndTesting」的其他資料
Project Title:
"Effectiveness Evaluation and Improving Strategy of Implementation of Environmental Testing System"
Project Subject:
"Environmental testing is an important cornerstone of environmental protection. Credible and reliabl
Project Year:
2020
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"Assessment on the revision of impact factors, sampling technologies and standards of indoor air qua
Project Subject:
" The topic of EPA project in 2014 is Assessment on the revision of impact factors, sampling techno
Project Year:
2014
Organizer:
"Department of Air Quality Protection & Noise Control"
Project Title:
"Monitoring Project for the River & Ocean Water Quality of Taichung City in 2016"
Project Subject:
""
Project Year:
2016
Organizer:
"Environmental Protection Bureau, Taichung City"
Project Title:
"Environmental quality Internet of Things promotion and management plan 2019"
Project Subject:
"EPA has been building the environmental IoT in Taiwan since 2017. Expecting that the implementation
Project Year:
2019
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Fine Particulate Matter (PM2.5) Chemical Speciation Monitoring and Analysis Project"
Project Subject:
"This study conducted an assigned mission of PM2.5 chemical speciation monitoring at Douliu, Chiayi,
Project Year:
2016
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"The Environmental Monitoring of the River, Ocean and Groundwater Water Quality in the Middle Area o
Project Subject:
"The aim of this project was to properly understand the changing trend of water quality in those typ
Project Year:
2018
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Technology Innovation for Carbon Fixation of Flue Gas by Microalgae "
Project Subject:
"In this project, novel technology for using microalgae to fix CO2 in industrial flue gas was develo
Project Year:
2010
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"The development and application of whole sediment chronic toxicity tests (2/2)"
Project Subject:
"Whole-sediment toxicity tests are increasingly being used in ecological risk assessments of sedimen
Project Year:
2014
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"Project of river water pollution source identification formation and practice(1/3)"
Project Subject:
"This project attempted to investigate spatial and temporal distributions of water pollution sources
Project Year:
2018
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"The Development of an Integrated Information System for Forensic of Environmental Pollution Sources
Project Subject:
"The objectives of this project are constructing auxiliary tools for environmental forensic, establi
Project Year:
2017
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"The Monitoring of Fine Suspended Particulate(PM2.5) in the Northern Part of Taiwan."
Project Subject:
"This project started from November 7th 2012 and will end on November 6th 2014. The project goal is
Project Year:
2012
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Performance Validation and Instrument Calibration for Air Quality Monitors and Related Facilities"
Project Subject:
"The major objectives of this project are to set up the metrological traceability of ambient air qua
Project Year:
2015
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Quality Assurance and Data Validation on Ozone precursor Monitoring from Photochemical Assesment Mo
Project Subject:
"The main objectives of this program included implementing the quality assurance audits of analytica
Project Year:
2017
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Project of Background Investigation for Chemical Substances Environmental Distribution, 2018"
Project Subject:
"The major aims of this project were to (1) investigate concerned chemicals in fifteen Taiwanese riv
Project Year:
2018
Organizer:
"Toxic and Chemical Substances Bureau"
Project Title:
"Ambient Air Quality Monitoring Plan in year 2012"
Project Subject:
"This project, i.e. Ambient Air Quality Monitoring plan in Yulin County in year 2012, began to carry
Project Year:
2012
Organizer:
"Environmental Protection Bureau Yunlin County"
Project Title:
"Quality Assurance Program for (FRM) PM2.5 Performance Evaluation(2014~2016)"
Project Subject:
"This report provides information of quality assurance for PM2.5 sampling activities from October 1,
Project Year:
2014
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"International Cooperation and Maintenance at the Lulin Atmospheric Background Station and Remote Si
Project Subject:
"In order to clarify the intercontinental and regional transport of air pollutants (for instance, ac
Project Year:
2020
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"The Project on Overseas Export and Environmental Analysis Technology"
Project Subject:
"In line with the government’s New Southbound Policy, The Environmental Protection Administration se
Project Year:
2020
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"Sampling/Monitoring Program for (FRM) PM2.5 in Central Taiwan (2018~2020)"
Project Subject:
" We monitored the PM2.5 by manual method in ten monitoring stations in central Taiwan. These ten
Project Year:
2018
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Study of Environmental Forensic Technology Development (3/4) –HRGC/ MS/IRMS, FTIR, and Raman Forens
Project Subject:
"The purpose of this study was to collect documentary information regarding the forensic technology
Project Year:
2015
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"Operation, maintenance and analysis plan of information display system for Tainan air quality monit
Project Subject:
"This project covered the operation and maintenance works of Air Quality Monitoring Station (AQMS) i
Project Year:
2016
Organizer:
"Environmental Protection Bureau of Tainan City"
Project Title:
"Compound specific isotope analysis of diesel fuels in a forensic investigation"
Project Subject:
"Based on the results accumulated in this project, we have achieved our goals to establish the proto
Project Year:
2019
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"Analyze and investigation of velocity and volumetric flow rate of gas stream in a duct"
Project Subject:
"The volumetric flow rate of complex flow field in duct was experimentally investigated in this proj
Project Year:
2015
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"Sampling/Monitoring Program for(FRM) PM2.5 in Southern Taiwan"
Project Subject:
" The purpose of this project was to monitor the mass concentration of fine suspended particle (P
Project Year:
2016
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Sampl ing/Moni tor ing Program for (FRM) PM2 .5 in Southern Taiwan"
Project Subject:
" The purpose of this project was to monitor the mass concentration of fine suspended particle (PM2
Project Year:
2014
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"VOC Continuous Monitoring and Sampling Project in Kaohsiung(2014~2015)"
Project Subject:
"In this project, evaluating the impact of industrial park to the residential area, the fixed open-p
Project Year:
2014
Organizer:
"Environmental Protection Bureau Kauhsiung City Government"
Project Title:
"106 Annual Report on the Achievements of Hualien County Air Quality Cleaning Area and Air Quality M
Project Subject:
"(A) indoor air quality operations
The inspection work for the second batch of premises has been car
Project Year:
2017
Organizer:
"Environmental Protection Bureau, Hualien County"
Project Title:
"Quality Assurance Program for (FRM) PM2.5 Performance Evaluation"
Project Subject:
"The executing period of this project is from July 1st 2012 to September 30th 2014. In order to reac
Project Year:
2012
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Microextraction technology development (3/4)- extraction method development for endocrine disruptin
Project Subject:
"This project is to investigate the determination of 40 compounds including endocrine disrupting che
Project Year:
2015
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"UV-Index Forecasting System and Instrument Calibration Laboratory "
Project Subject:
"The main task of this project, “UV Forecast System and Monitoring Instrument Calibration Lab.-Fisca
Project Year:
2014
Organizer:
"Department of Environmental Monitoring & Information Management"
行政院環境保護署 的其他資料集
空氣品質小時值_苗栗縣_三義站
每小時更新更新,185謝小姐 | 02-2311-7722#2386 | 2022-01-14 01:03:59
行政院環境保護署全國模範清潔人員名單
每年更新更新,33林小姐 | (04)2252-1718#53610 | 2022-01-14 01:18:05
行政院環境保護署環境用藥販賣業地理資料
不定期更新更新,51薛先生 | 02-2325-7399#55413 | 2023-07-27 01:02:55
行政院環境保護署場址勘查紀錄表
不定期更新更新,126賴小姐 | 02-2383-2389#8102 | 2022-01-15 01:12:17
行政院環境保護署環境教育人員認證展延 【常見問答】
不定期更新,46蘇小姐 | (03)4020789分機669 | 2022-01-15 01:11:10
行政院環境保護署
行政院環境保護署前瞻基礎建設計畫特別預算會計月報
每1月更新,52鄭小姐 | 02-23117722#2156 | 2023-08-09 01:05:39
行政院環境保護署歷年環保署農地_全國重金屬污染潛勢之管制及調查計畫
不定期更新更新,98謝先生 | (02)23832389*8302 | 2022-01-14 01:20:23
行政院環境保護署縣市(苗栗縣)小時值-每小時
每小時更新更新,801謝小姐 | 02-2311-7722#2386 | 2022-01-14 01:00:51
行政院環境保護署臺東縣水量水質自動監測連線傳輸監測紀錄值即時資料集
不定期更新更新,45程先生 | 02-2311-7722#2833 | 2023-08-09 01:04:06
行政院環境保護署環保署職員官等年齡統計資料
不定期更新更新,43黃小姐 | 02-23117722分機2132 | 2022-01-15 01:12:56
行政院環境保護署
行政院環境保護署環境保護基金附屬單位法定預算
每1年更新,44郭小姐 | 02-2311-7722#2164 | 2023-08-09 01:05:43
行政院環境保護署建檔公廁明細-嘉義市
不定期更新更新,223賴先生 | 04-2252-1718#53686 | 2023-07-27 01:01:59
行政院環境保護署病媒防治業地理資料
不定期更新更新,34薛先生 | 02-2325-7399#55413 | 2023-07-27 01:02:56
行政院環境保護署獎勵民眾檢舉違反水污染防治法案件指導原則
不定期更新,40簡小姐 | 02-2311-7722#2818 | 2022-01-15 01:13:07
行政院環境保護署固定污染源-煙道基本參數檔
不定期更新更新,104陳小姐 | 02-2371-2121#6216 | 2022-01-14 01:02:45
行政院環境保護署
碳足跡排放係數
不定期更新更新,97陳小姐 | 02-2311-7722#2943 | 2022-01-15 01:10:00
行政院環境保護署機關綠色採購績效評核作業要點
不定期更新更新,43王先生 | 02-23117722#2921 | 2022-01-14 01:18:00
行政院環境保護署南投縣水量水質自動監測連線傳輸監測紀錄值即時資料集
不定期更新更新,40程先生 | 02-2311-7722#2833 | 2023-08-09 01:04:11
行政院環境保護署空氣品質小時值_高雄市_橋頭站
每1時更新,371陳先生 | 02-2311-7722#2386 | 2023-08-02 00:57:43
行政院環境保護署空氣品質小時值_雲林縣_臺西站
每1時更新,123陳先生 | 02-2311-7722#2386 | 2023-08-02 00:57:49
行政院環境保護署
環境影響評估案件摘要資料
每2月更新,225黃先生 | 02-23117722#2748 | 2023-08-06 01:03:57
行政院環境保護署再生粒料毒性特性溶出試驗結果
不定期更新更新,51許先生 | 02-2311-7722#2641 | 2022-01-14 01:18:39
行政院環境保護署固定污染源設備元件揮發性有機物洩漏檢測申報資料
每3月更新,253戴先生 | 02-2311-7722#6208 | 2023-08-07 01:02:40
行政院環境保護署廢棄物質最終處置資訊網相關新聞
每月更新更新,55許先生 | 02-2311-7722#2641 | 2022-01-14 01:24:14
行政院環境保護署大型垃圾焚化廠操作營運情形
每月更新更新,123謝小姐 | 02-23117722#2103 | 2022-01-14 01:21:17
行政院環境保護署
縣市清運機具統計資料
每半年更新更新,39陳小姐 | (04)2252-1718#53406 | 2022-01-14 01:22:13
行政院環境保護署通訊傳播事業廢棄物再利用機構資料
每年更新更新,56李小姐 | 02-2311-7722#2633 | 2022-01-14 01:26:20
行政院環境保護署環境督察總隊對污染源裁處資訊
每1月更新,192蘇先生 | 04-2252-1718#51305 | 2023-04-15 01:01:35
行政院環境保護署行政院環境保護署環境保護產品驗證機構管理要點
每季更新更新,44孫小姐 | 02-23117722#2926 | 2022-01-15 01:13:11
行政院環境保護署環評主管機關受理審查之環境影響調查報告
每2月更新,88黃先生 | 02-23117722#2748 | 2023-08-05 01:01:16
行政院環境保護署