time1: 0 time2: 0 time3: 0 time4: 0 total: 0 ""2014"The detection method of total volatile organic compounds
台灣資料通-開放資料查詢 台灣資料通-公開資料預覽查詢
關鍵字資料搜尋

""2014"The detection method of total volatile organic compounds

""2014"The detection method of total volatile organic compounds 」於資料集「EPQSummary_Air」由單位「行政院環境保護署」的郭先生所提供,聯繫電話是02-2311-7722 EXT.2399,最近更新時間為:2022-01-15 01:13:50。 欄位Project Title的內容是"" , 欄位Project Subject的內容是"The detection method of total volatile organic compounds (VOC) in water was promulgated. The sample should be collected by purge and trap and analyzed by gas chromatography with mass spectrometry (NIEA W785.55B). The total VOC concentration is calculated by summing the concentration of individual components from GC/MS analysis. However, the results cannot represent the actual emission if the VOC from cooling water in petrochemical industry is not on the target compound list. A study of the VOC determination of VOC in water was conducted to elevate the regulating of fugitive VOC emissions. As a result of this research, a quantitative method and its SOP for VOC in water has been developed and validated by laboratory and pilot study. 20 of several established regulatory requirements and research for VOC emissions from wastewater treatment facilities have been reviewed in this project. The TCEQ’s El Paso stripper / FID method (as methane) was chosen for this study. This method and the equipment have been validated in this project, confirming its applicability to detect VOC in water, detection limits being on the order of 0.010 mg/L. The VOC in 9 cooling towers from domestic petrochemical industry was monitored at 4 sites. The water samples were on-site monitored by using El Paso stripper / FID as well as shipped to the laboratory for analysis by GC/MS for 68 VOCs which revealed the presence of chloroform, acetone, 2-propanol and styrene where acetone and 2-propanol are not regulated. The total VOC concentration, as the sum of the concentration of chloroform, styrene and other compounds which were not detected (as 0.5×MDL), of 4 cooling water were 0.01930, 0.01309, 0.01989 and 0.01528 mg/L by GC/MS. The total VOC from the measurements of stripping / FID were 0.0208, 0.0128, 0.0112 and 0.0189 mg/L. There is no significant correlation between these results furthermore both results are much less than the current permitted level of cooling water, 5 mg/L." , 欄位Project Year的內容是2014 , 欄位Organizer的內容是"Environmental Analysis Laboratory" , 欄位Executive Unit的內容是"財團法人中興工程顧問社" , 欄位Reporting download URL的內容是https://epq.epa.gov.tw/project/filedownload.aspx?fid=73815 , 欄位Publish Date的內容是20150201

Project Title

""

Project Subject

"The detection method of total volatile organic compounds (VOC) in water was promulgated. The sample should be collected by purge and trap and analyzed by gas chromatography with mass spectrometry (NIEA W785.55B). The total VOC concentration is calculated by summing the concentration of individual components from GC/MS analysis. However, the results cannot represent the actual emission if the VOC from cooling water in petrochemical industry is not on the target compound list. A study of the VOC determination of VOC in water was conducted to elevate the regulating of fugitive VOC emissions. As a result of this research, a quantitative method and its SOP for VOC in water has been developed and validated by laboratory and pilot study. 20 of several established regulatory requirements and research for VOC emissions from wastewater treatment facilities have been reviewed in this project. The TCEQ’s El Paso stripper / FID method (as methane) was chosen for this study. This method and the equipment have been validated in this project, confirming its applicability to detect VOC in water, detection limits being on the order of 0.010 mg/L. The VOC in 9 cooling towers from domestic petrochemical industry was monitored at 4 sites. The water samples were on-site monitored by using El Paso stripper / FID as well as shipped to the laboratory for analysis by GC/MS for 68 VOCs which revealed the presence of chloroform, acetone, 2-propanol and styrene where acetone and 2-propanol are not regulated. The total VOC concentration, as the sum of the concentration of chloroform, styrene and other compounds which were not detected (as 0.5×MDL), of 4 cooling water were 0.01930, 0.01309, 0.01989 and 0.01528 mg/L by GC/MS. The total VOC from the measurements of stripping / FID were 0.0208, 0.0128, 0.0112 and 0.0189 mg/L. There is no significant correlation between these results furthermore both results are much less than the current permitted level of cooling water, 5 mg/L."

Project Year

2014

Organizer

"Environmental Analysis Laboratory"

Executive Unit

"財團法人中興工程顧問社"

Publish Date

20150201

「""2014"The detection method of total volatile organic compounds 」所屬的資料集:「EPQSummary_Air」的其他資料

Project Title: "To Open The Dome: PM2.5 public good governance academic forum project"
Project Subject: "The program contains three regional forums, an academic forum and academic visit.The main themes in
Project Year: 2015
Organizer: "Department of Air Quality Protection & Noise Control"

Project Title: "Evaluating Regional Energy Conservation and Carbon Reduction Project for International Cooperation
Project Subject: "If the model provides the possible effects of policy programs, decision makers can more quickly sel
Project Year: 2015
Organizer: "Solution integration office"

Project Title: "none"
Project Subject: "none"
Project Year: 2016
Organizer: "Nantou County Environmental Protection Bureau"

Project Title: "2014~2015 Inspection and Management Plan of Vehicles Emission Inspection Station"
Project Subject: " "
Project Year: 2014
Organizer: "Environmental Protection Bureau Kauhsiung City Government"

Project Title: "Volatile Organic Compounds and Continuous Automatic Monitoring of Pollution Sources and Control Pla
Project Subject: "Taoyuan City, the number of fixed sources of pollution 2,586, which are based on the Environmental
Project Year: 2017
Organizer: "Taoyuan County Government Environment Protection Bureau"

Project Title: "2015 Taichung City Environmental Quality Monitoring Station Operation And Maintance Project"
Project Subject: "This project was implemented from Jan. 20, 2015 to Dec. 31, 2015. All the tasks defined in the cont
Project Year: 2015
Organizer: "Environmental Protection Bureau, Taichung City"

Project Title: "Moving pollution source inspection control project in 2014"
Project Subject: "Mobile pollution sources is one of the main cause for the air quality decline, in order to improve
Project Year: 2014
Organizer: "Environmental Protection Bureau of Yi-Lan County"

Project Title: "2018 Hualien City Mobile Pollution Source control and Parking idling flameout management Project"
Project Subject: "From the date of completion of the contract signing, in order to make the project smoothly promoted
Project Year: 2018
Organizer: "Environmental Protection Bureau, Hualien County"

Project Title: "Chiayi City folk activities, catering and open burning of the Air Pollution Control plan"
Project Subject: "The results of the implementation report are summarized below:A. The Investigation of air pollution
Project Year: 2015
Organizer: "Environmental Protection Bureau, Chiayi City"

Project Title: "Emission Estimation and Concentration Monitoring of PM2.5 in Keelung Port"
Project Subject: "-"
Project Year: 2016
Organizer: "Bureau of Environmental Protection, Keelung City"

Project Title: "Early warning strain plan of the emitted dust along Jhuoshuei River in 2012."
Project Subject: "According to the air quality data of monitoring station near Zhuoshui river, when the arrival of th
Project Year: 2012
Organizer: "Environmental Protection Bureau Yunlin County"

Project Title: "Ambient Air Quality Monitoring Plan in year 2016"
Project Subject: "This project has been started on August 26, 2016. The project scope included operation, maintenance
Project Year: 2016
Organizer: "Environmental Protection Bureau Yunlin County"

Project Title: "The Integration Plan of Air Quality to Manintain, Improve, scheme and street dust"
Project Subject: "The main work items of this project include executing air qualityanalysis, proposing air pollution
Project Year: 2015
Organizer: "Environmental Protection Bureau, Taipei County"

Project Title: "Air Pollutant Information Integration in Coastal Industrial Park"
Project Subject: "The project “Air Pollutant Information Integration in Coastal Industrial Park” has been executed si
Project Year: 2012
Organizer: "Environmental Protection Bureau Yunlin County"

Project Title: "The project offugitive emission sourcescontrol maintenance management of Airquality purification ar
Project Subject: "The primary mission of the project is to promote “management and maintenance of air quality purific
Project Year: 2015
Organizer: "Environmental Protection Bureau Yunlin County"

Project Title: "River Fugitive Dust and Improvement Plan for Gaoping River in Pingtung County, 106"
Project Subject: "The execution period of this project is from May 18, 2017 to May 17, 2018. All contract goals of wo
Project Year: 2017
Organizer: "Environmental Protection Bureau, Pingtung County"

Project Title: "UV-Index Monitoring Analysis and Instrument Calibration Laboratory"
Project Subject: "The main task of this project, “106-107 UV-Index Monitoring Analysis and Instrument Calibration Lab
Project Year: 2017
Organizer: "Department of Environmental Monitoring & Information Management"

Project Title: "The main pollution source inspection control and poor air quality improvement process project in Ta
Project Subject: "Status analysis of air quality (1) According to the Air Quality Index (AQI), analyzed the AQI>100 r
Project Year: 2018
Organizer: "Environmental Protection Bureau of Tainan City"

Project Title: "The project of management for stationary sources permit system and check the receivable of air poll
Project Subject: "This is a continuous administrative controlling project. The main work of the project can be divide
Project Year: 2018
Organizer: "Taoyuan County Government Environment Protection Bureau"

Project Title: "2017 Annual Hsinchu County Indoor Air Quality Management Project"
Project Subject: "Contemporary people spend most of their indoors. The quality of the air indoors has a direct impact
Project Year: 2017
Organizer: "HsinChu County Environment Protection Bureau"

Project Title: "Project of Year 2018 for Control and Inspection of Stationary sources"
Project Subject: "The execution duration of this project is from Nonmember 6th, 2018 to May 5th, 2019.The final resul
Project Year: 2018
Organizer: "Environmental Protection Bureau Yunlin County"

Project Title: "Air quality purification area inventory、assessment and maintenance evaluation project."
Project Subject: "Air pollution control is one of the important works to protect environment. Therefore, the Environm
Project Year: 2015
Organizer: "Department of Air Quality Protection & Noise Control"

Project Title: "Fugitive Pollution Source Control Plan in 2018"
Project Subject: "A total of 318 open-air burning inspections were completed, of which 135 were burned and 183 were b
Project Year: 2018
Organizer: "Environmental Protection Bureau Yunlin County"

Project Title: "Mobile Sources of Pollution Control and Inspection Project of Tainan City, 2013"
Project Subject: "The quantity goals of this project achieved are as the follow table. The main duty of this project
Project Year: 2013
Organizer: "Environmental Protection Bureau of Tainan City"

Project Title: "The emission management of port and the other non-road transportation mobile sources"
Project Subject: "Since 2009, Environmental Protection Administration of Taiwan (EPAT) has been conducting “Establish
Project Year: 2017
Organizer: "Department of Air Quality Protection & Noise Control"

Project Title: "The project of enhancing street fugitive dust washing and sweeping program for Yunlin County in 201
Project Subject: "The project, has completed the following main events, and the results are described below:1. The st
Project Year: 2014
Organizer: "Environmental Protection Bureau Yunlin County"

Project Title: "106 Taitung County in response to climate change implementation plan"
Project Subject: "In order to promote Taitung County's response to the impact of climate change, put forward a comple
Project Year: 2017
Organizer: "Taitung County Environment Protection Bureau"

Project Title: "The project of CEMS installation institution review and information management of the stationary so
Project Subject: "As the issue of air pollution has gradually been taken seriously by the public, the government has
Project Year: 2018
Organizer: "Department of Air Quality Protection & Noise Control"

Project Title: "Pingtung County Air Quality Warning and Severe Deterioration and Chaozhou Air Quality Maintenance A
Project Subject: "The 2018 Pingtung County Air Quality Warning and Severe Deterioration of strain and Chaozhou Air Qu
Project Year: 2018
Organizer: "Environmental Protection Bureau, Pingtung County"

Project Title: "Penhu County 2015 Mobile Sources Audition and Control Project"
Project Subject: "On motorbike pollution control, according to the data on EPA moter vehicles emission regular test i
Project Year: 2015
Organizer: "Environmental Protection Bureau, Penghu County"

行政院環境保護署 的其他資料集

經過活動斷層範圍環境影響說明書

每2月更新,87

黃先生 | 02-23117722#2748 | 2023-08-05 01:01:11

行政院環境保護署

列管廢棄物棄置場址

每1月更新,39

黃小姐 | 04-22521718*53606 | 2023-08-09 01:04:05

行政院環境保護署

環境用藥販賣業許可執照資料

每3月更新,148

薛先生 | 02-2325-7399#55413 | 2023-07-27 01:02:58

行政院環境保護署

空氣品質小時值_桃園市_觀音站

每小時更新更新,179

謝小姐 | 02-2311-7722#2386 | 2022-01-14 01:03:49

行政院環境保護署

空氣品質小時值_臺北市_古亭站

每1時更新,136

陳先生 | 02-2311-7722#2386 | 2023-08-02 00:58:11

行政院環境保護署

焚化廠基本資料

每月更新更新,54

吳先生 | 04-22521718#53526 | 2022-01-15 01:15:18

行政院環境保護署

建檔公廁明細-南投縣

不定期更新更新,126

賴先生 | 04-2252-1718#53686 | 2023-07-27 01:02:06

行政院環境保護署

空氣品質監測站基本資料

不定期更新更新,118

陳先生 | 02-2311-7722#2386 | 2023-08-07 01:01:47

行政院環境保護署

飲用水設備維護管理稽查成果

不定期更新更新,89

黃先生 | 02-23117722-2881 | 2022-01-15 01:10:29

行政院環境保護署

空氣品質小時值_宜蘭縣_宜蘭站

每1時更新,80

陳先生 | 02-2311-7722#2386 | 2023-08-02 00:57:31

行政院環境保護署

公害糾紛裁決委員會委員名單

不定期更新更新,39

謝先生 | 02-2311-7722#2962 | 2022-01-15 01:12:55

行政院環境保護署

行政院環境保護署「資料開放諮詢小組」委員名單

不定期更新更新,50

林小姐 | 02-2311-7722#2365 | 2022-01-15 01:12:45

行政院環境保護署

空氣品質小時值_臺南市_臺南站

每1時更新,96

陳先生 | 02-2311-7722#2386 | 2023-08-02 00:57:45

行政院環境保護署

環評主管機關受理審查之因應對策

每2月更新,41

黃先生 | 02-23117722#2748 | 2023-08-05 01:01:17

行政院環境保護署

廢棄物質最終處置資訊網會議資料

每月更新更新,35

許先生 | 02-2311-7722#2641 | 2022-01-14 01:24:13

行政院環境保護署

汽車新車審驗資料

每月更新更新,165

王先生 | 02-23712121#6306 | 2022-01-14 01:18:29

行政院環境保護署

環保署遊說法辦理情形

不定期更新更新,43

包先生 | 02-23117722 #2223 | 2022-01-15 01:13:30

行政院環境保護署

鹿林山測站基本資料

不定期更新更新,38

謝小姐 | 02-2311-7722#2386 | 2022-01-14 01:05:02

行政院環境保護署

光化測站小時值資料

每1月更新,75

陳先生 | 02-2311-7722#2386 | 2023-08-03 00:59:17

行政院環境保護署

縣市(花蓮縣)小時值-每小時

每小時更新更新,123

謝小姐 | 02-2311-7722#2386 | 2022-01-14 01:01:13

行政院環境保護署

事業廢棄物申報統計

每1年更新,123

顏先生 | 02-23117722#2109 | 2023-07-30 01:00:57

行政院環境保護署

環評主管機關受理審查之環境影響說明書

每2月更新,114

黃先生 | 02-23117722#2748 | 2023-08-06 01:04:32

行政院環境保護署

建檔公廁明細-新北市

不定期更新更新,135

賴先生 | 04-2252-1718#53686 | 2023-07-27 01:02:01

行政院環境保護署

交通噪音監測站位置圖

不定期更新更新,41

章小姐 | 02-23712121#6407 | 2023-07-27 01:06:02

行政院環境保護署

總碳氫化合物(THC)監測小時值(每小時提供)

每小時更新更新,107

謝小姐 | 02-2311-7722#2386 | 2022-01-14 01:05:09

行政院環境保護署

核能四廠環評監督委員會會議紀錄

不定期更新更新,38

陳先生 | 04-2252-1718#51207 | 2023-08-09 01:04:33

行政院環境保護署

環保標章認證實驗室資料

每1月更新,43

黃先生 | 02-23117722#2932 | 2023-07-27 01:01:44

行政院環境保護署

空氣品質監測小時值(一般污染物,每日更新)

每日更新更新,170

謝小姐 | 02-2311-7722#2386 | 2022-01-14 01:01:07

行政院環境保護署

空氣品質小時值_高雄市_鳳山站

每1時更新,144

陳先生 | 02-2311-7722#2386 | 2023-08-02 00:57:42

行政院環境保護署

宜蘭縣水量水質自動監測連線傳輸監測紀錄值即時資料集

不定期更新更新,52

許先生 | 02-2311-7722#2831 | 2022-01-18 01:24:52

行政院環境保護署