"Development of analytical tools for measuring and characterizin
「"Development of analytical tools for measuring and characterizin」於資料集「EPQSummary_EnvironmentalMonitoringAndTesting」由單位「行政院環境保護署」的陳先生所提供,聯繫電話是02-2311-7722#2386,最近更新時間為:2023-07-30 01:01:45。 欄位Project Title的內容是"Development of analytical tools for measuring and characterizing nanomaterials in the environment" , 欄位Project Subject的內容是"The particle emission characteristics and chemical components of six kinds of textiles containing silver nanoparticles and three kinds of silver nano-sprays were tested in the present study. For the textiles containing silver nanoparticles, the sock A with nanoMark contains low silver nanoparticle concentration of 12.63 ± 0.57 μg/g, which were distributed uniformly within the whole sock. The sock B and C without nanoMark contain higher silver nanoparticle concentration of 2499.10 ± 122.59 and 34.42 ± 4.74 μg/g, respectively, as comparted with the sock A, in which the silver nanoparticles were concentrated on toes’ spot. The silver nanoparticle concentration in the sock D was only observed on the toes’ spot of 2.89 μg/g. The towels and the handkerchief with nanoMark contain 8.75 and 4.73 μg /g silver nanoparticle concentration, respectively. After the first washing, textiles containing silver nanoparticles were found to release more metals related to the materials added in the textiles, as compared to the tested socks, towels and handkerchiefs. The released metal concentrations decreased with increasing times of washing. After 20 times of washing, the sock A emitted the lowest particle concentration and released the lowest metal concentration among the all textiles. Besides, according to the results analyzed by TEM and EDS, the silver signal is very low, suggesting that the silver nanoparticles added in the sock A is not easy to be emitted by rubbing.For the nano-sprays containing silver, the experimental results show that risk of nanoparticle exposure for human body is very high within 20 to 60 seconds emission test. The mass concentration distributions of three nano-sprays containing silver measured by MOUDI were slightly higher than those measured by ELPI of 8, 6 and 8 %. The mass concentration distributions of nano-sprays A and B showed bimodal distributions, in which the first peak was located between 1-3 μm and the second peak was located between 0.18-0.48 μm. Nano-sprays C shows single modal mass concentration distribution with peak in the size range between 0.29-0.44 μm.Another work item in this project is to measure the number concentration and mass concentration distribution of atmospheric nanoparticles. The average number concentration measured in the Zhongshan site was 1.8 ± 1.2×104 #/cm3, which highly correlated with NOx and CO influenced by traffic emissions. The average number concentration was 8.0 ± 5.4×103 #/cm3 in Shalu site, which slightly correlated with O3 concentration influenced by photochemical reaction and industries emissions. The average number concentration was measured to be 4.7 ± 1.8×103 #/cm3 in Douliou site and the correlation between SO2 concentration and the average number concentration is high due to traffic emissions and photochemical reaction. Based on the number and mass concentration measured in the sampling as the aforementioned, the effective density was calculated to convert the mass concentration measured by MOUDI into number concentration and surface concentration. The results showed that although the mass ratio of PM0.1/PM2.5 of 7.9 ± 4.4 % was low, the number concentration ratio of PM0.1/PM2.5 was 89.0 ± 5.5 %, and the surface concentration ratio was 42.1 ± 12.8 %. Therefore, we should pay attention to the adverse effect of PM0.1 on human health. The experimental results showed that the submicron particle number concentration measured by APS (Aerodynamic particle sizer, Model 3321, TSI Incorporated, USA) was lower than those measured by OPC (Optical particle counter, Model 1.108, GRIMM technology inc., USA) because the APS detection efficiency for particles with size smaller than 0.7 μm is low. Besides, the mass concentration measured by PM2.5 manual sampler PQ-200 (BGI Inc., USA) was highly correlated with those measured by DustTrak (DustTrak DRX 8533, TSI Incorporated, USA) (R2=..." , 欄位Project Year的內容是2014 , 欄位Organizer的內容是"Environmental Analysis Laboratory" , 欄位Executive Unit的內容是"國立交通大學環境工程研究所" , 欄位Reporting download URL的內容是https://epq.epa.gov.tw/project/filedownload.aspx?fid=76406 , 欄位Publish Date的內容是20150201 。
Project Title
"Development of analytical tools for measuring and characterizing nanomaterials in the environment"
Project Subject
"The particle emission characteristics and chemical components of six kinds of textiles containing silver nanoparticles and three kinds of silver nano-sprays were tested in the present study. For the textiles containing silver nanoparticles, the sock A with nanoMark contains low silver nanoparticle concentration of 12.63 ± 0.57 μg/g, which were distributed uniformly within the whole sock. The sock B and C without nanoMark contain higher silver nanoparticle concentration of 2499.10 ± 122.59 and 34.42 ± 4.74 μg/g, respectively, as comparted with the sock A, in which the silver nanoparticles were concentrated on toes’ spot. The silver nanoparticle concentration in the sock D was only observed on the toes’ spot of 2.89 μg/g. The towels and the handkerchief with nanoMark contain 8.75 and 4.73 μg /g silver nanoparticle concentration, respectively. After the first washing, textiles containing silver nanoparticles were found to release more metals related to the materials added in the textiles, as compared to the tested socks, towels and handkerchiefs. The released metal concentrations decreased with increasing times of washing. After 20 times of washing, the sock A emitted the lowest particle concentration and released the lowest metal concentration among the all textiles. Besides, according to the results analyzed by TEM and EDS, the silver signal is very low, suggesting that the silver nanoparticles added in the sock A is not easy to be emitted by rubbing.For the nano-sprays containing silver, the experimental results show that risk of nanoparticle exposure for human body is very high within 20 to 60 seconds emission test. The mass concentration distributions of three nano-sprays containing silver measured by MOUDI were slightly higher than those measured by ELPI of 8, 6 and 8 %. The mass concentration distributions of nano-sprays A and B showed bimodal distributions, in which the first peak was located between 1-3 μm and the second peak was located between 0.18-0.48 μm. Nano-sprays C shows single modal mass concentration distribution with peak in the size range between 0.29-0.44 μm.Another work item in this project is to measure the number concentration and mass concentration distribution of atmospheric nanoparticles. The average number concentration measured in the Zhongshan site was 1.8 ± 1.2×104 #/cm3, which highly correlated with NOx and CO influenced by traffic emissions. The average number concentration was 8.0 ± 5.4×103 #/cm3 in Shalu site, which slightly correlated with O3 concentration influenced by photochemical reaction and industries emissions. The average number concentration was measured to be 4.7 ± 1.8×103 #/cm3 in Douliou site and the correlation between SO2 concentration and the average number concentration is high due to traffic emissions and photochemical reaction. Based on the number and mass concentration measured in the sampling as the aforementioned, the effective density was calculated to convert the mass concentration measured by MOUDI into number concentration and surface concentration. The results showed that although the mass ratio of PM0.1/PM2.5 of 7.9 ± 4.4 % was low, the number concentration ratio of PM0.1/PM2.5 was 89.0 ± 5.5 %, and the surface concentration ratio was 42.1 ± 12.8 %. Therefore, we should pay attention to the adverse effect of PM0.1 on human health. The experimental results showed that the submicron particle number concentration measured by APS (Aerodynamic particle sizer, Model 3321, TSI Incorporated, USA) was lower than those measured by OPC (Optical particle counter, Model 1.108, GRIMM technology inc., USA) because the APS detection efficiency for particles with size smaller than 0.7 μm is low. Besides, the mass concentration measured by PM2.5 manual sampler PQ-200 (BGI Inc., USA) was highly correlated with those measured by DustTrak (DustTrak DRX 8533, TSI Incorporated, USA) (R2=..."
Project Year
2014
Organizer
"Environmental Analysis Laboratory"
Executive Unit
"國立交通大學環境工程研究所"
Reporting download URL
Publish Date
20150201
「"Development of analytical tools for measuring and characterizin」所屬的資料集:「EPQSummary_EnvironmentalMonitoringAndTesting」的其他資料
Project Title:
"Yunlin County Volatile Hazardous Air Pollutants Monitoring and survey Plan in year 2019"
Project Subject:
"(1) The ambient hazardous air pollutant (HAP) monitoring data from Mai-Liao special industrial park
Project Year:
2019
Organizer:
"Environmental Protection Bureau Yunlin County"
Project Title:
"The Enviroment Monitoring of the Water Quality in the Northern Area of Taiwan from 2018 to 2021"
Project Subject:
"This project carries on water quality monitoring to four kinds of water bodies of ten counties and
Project Year:
2018
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Unmanned Aircraft System for Taiwan coastal and environmental monitoring"
Project Subject:
"This project conducted a survey of coastline's current situations via UAS (Unmanned Aircraft System
Project Year:
2014
Organizer:
"Department of Environmental Sanitation & Toxic Substance Management"
Project Title:
"2014 Atmospheric Fine Particulates Monitoring and Analysis Project in Kinmen County"
Project Subject:
"The project was carried out from Feb. 19th to Dec. 20, 2013. The main work items of this project in
Project Year:
2014
Organizer:
"Environmental Protection Bureau, Kinmen County"
Project Title:
"The development and application of whole sediment chronic toxicity tests (2/2)"
Project Subject:
"Whole-sediment toxicity tests are increasingly being used in ecological risk assessments of sedimen
Project Year:
2014
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"The Monitoring Of Fine Suspended Particulate(PM2.5) in the Central"
Project Subject:
"We monitored the PM2.5 by manual method in ten monitoring stations in central Taiwan. These ten sta
Project Year:
2012
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"107 Hualien County Air Quality Purification Zone and Air Quality Monitoring, CEMS Supervision and M
Project Subject:
"(1) Indoor air quality operations A total of 29 inspections were carried out in the first and se
Project Year:
2018
Organizer:
"Environmental Protection Bureau, Hualien County"
Project Title:
"Auditing project of the stationary source air pollutants analysis data quality"
Project Subject:
"This auditing was designed for data quality of air pollutant analysis from June 2018 to December 20
Project Year:
2018
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"Air Quality Monitoring Van used in Petrochemical Industrial Park specifically operated and maintain
Project Subject:
"The project started in June 10th, 2015, planned to include the petrochemical vehicle monitoring ope
Project Year:
2015
Organizer:
"Environmental Protection Bureau Yunlin County"
Project Title:
"Project for High-Efficiency Smart WIoT Networking Application"
Project Subject:
"In the wake of Taiwan's rapid economic development, industrialization and urbanization has exerted
Project Year:
2021
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Study of Environmental Forensic Technology Development (4/4) – Platform Establishment and Applicati
Project Subject:
"The purposes of the project were (1) to integrate environmental sampling, including technology info
Project Year:
2016
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"Air Quality & Environment Monitoring Popular Science Project"
Project Subject:
"This project assists the Environmental Protection Agency of the Executive Yuan to implement the ent
Project Year:
2021
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Effectiveness Evaluation and Improving Strategy of Implementation of Environmental Testing System"
Project Subject:
"Environmental testing is an important cornerstone of environmental protection. Credible and reliabl
Project Year:
2020
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"Sampling/Monitoring Program for (FRM) PM2.5 in Northern Taiwan"
Project Subject:
"This project started from November 1st 2014 and will end on October 31th 2016. The project goal is
Project Year:
2014
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"The Environmental Monitoring of the Water Quality in the Middle Area of Taiwan from 2015 to 2018 "
Project Subject:
"The aim of this project was to properly understand the changing trend of water quality in those typ
Project Year:
2015
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Development and application of carbon and Pb isotopes analysis technology in fine particles"
Project Subject:
"The objective of this study is to investigate the potential pollution sources of PM2.5 in Kaohsiung
Project Year:
2020
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Indoor air quality inspection, counseling, and control plan of Hsinchu City in 2016"
Project Subject:
"1. Direct-reading equipment inspection operationsThe IAQ of 133 public and private premises were te
Project Year:
2016
Organizer:
"Bureau of Environmental Protection Hsin-Chu"
Project Title:
"The project of CEMS installation institution review and information management of the stationary so
Project Subject:
"The Continuous Emission Monitoring System (hereinafter referred to as “CEMS”) of air pollution for
Project Year:
2016
Organizer:
"Department of Air Quality Protection & Noise Control"
Project Title:
"Study of Indoor and Outdoor Long-term Environmental Non-Ionizing Radiation Monitoring Technologies"
Project Subject:
"Nowadays, electricity and electromagnetic (EM) waves play a very important role in our daily lives
Project Year:
2014
Organizer:
"Department of Air Quality Protection & Noise Control"
Project Title:
"Environmental quality sensing Internet of things to promote and Project Management Plan"
Project Subject:
"The trend following the rise of the internet of things (IOT) technology in the current scientific a
Project Year:
2018
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
""
Project Subject:
"The major objective of the project aims to develop sampling and analysis technology of volatile org
Project Year:
2015
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"Project of Background Investigation for Chemical Substances Environmental Distribution, 2018"
Project Subject:
"The major aims of this project were to (1) investigate concerned chemicals in fifteen Taiwanese riv
Project Year:
2018
Organizer:
"Toxic and Chemical Substances Bureau"
Project Title:
"The Establishment of Taiwan Environmental Health Vector and Pest Monitoring and Chemical Control Te
Project Subject:
"Cypermethrin, tetramethrin, permethrin, deltamethrin, chlorpyrifos, fenitrothion, pirimiphos-methyl
Project Year:
2018
Organizer:
"Toxic and Chemical Substances Bureau"
Project Title:
"Indoor air quality inspection, counseling, and control plan of Hsinchu City in 2016"
Project Subject:
"1. Direct-reading equipment inspection operations
The IAQ of 133 public and private premises were t
Project Year:
2016
Organizer:
"Bureau of Environmental Protection Hsin-Chu"
Project Title:
"Developing the Local PM2.5 Monitoring System and the Volunteer Program for Air Protection for the M
Project Subject:
"In order to remind people of self-protection and raise public awareness of air pollution and reduce
Project Year:
2017
Organizer:
"Department of Air Quality Protection & Noise Control"
Project Title:
"Technology Innovation for Carbon Fixation of Flue Gas by Microalgae "
Project Subject:
"In this project, novel technology for using microalgae to fix CO2 in industrial flue gas was develo
Project Year:
2010
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"UV-Index Forecasting System and Instrument Calibration Laboratory "
Project Subject:
"The main task of this project, “UV Forecast System and Monitoring Instrument Calibration Lab.-Fisca
Project Year:
2014
Organizer:
"Department of Environmental Monitoring & Information Management"
Project Title:
"Investigation of the correlation between the organic contamination level in soils and the actual co
Project Subject:
"Concentrations of organic contaminants in common productive soils based on the total soil mass give
Project Year:
2014
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"Study of the metal stable isotopes on environmental forensics (2/2)"
Project Subject:
"In the first year of this project, we have successfully developed an analytical protocol for tracin
Project Year:
2018
Organizer:
"Environmental Analysis Laboratory"
Project Title:
"The Monitoring Of Fine Suspended Particulate(PM2.5) in the Central"
Project Subject:
"We monitored the PM2.5 by manual method in ten monitoring stations in central Taiwan. These ten sta
Project Year:
2012
Organizer:
"Department of Environmental Monitoring & Information Management"
行政院環境保護署 的其他資料集
行政院環境保護署環境保護產品申請審查作業規範
每季更新更新,41孫小姐 | 02-23117722#2926 | 2022-01-15 01:13:10
行政院環境保護署地下水污染物監測及管制標準
不定期更新更新,106陳小姐 | 02-2383-2389#8207 | 2022-01-14 01:20:11
行政院環境保護署新竹縣水量水質自動監測連線傳輸監測紀錄值即時資料集
不定期更新更新,44程先生 | 02-2311-7722#2833 | 2023-08-09 01:04:14
行政院環境保護署核能四廠環境監測資料
不定期更新更新,39陳先生 | 04-22521718#51207 | 2022-01-14 01:22:00
行政院環境保護署焚化廠營運年報
每1年更新,112莊先生 | 04-22521718#53523 | 2023-08-07 01:02:34
行政院環境保護署
縣市(新竹縣)小時值-每小時
每1時更新,107陳先生 | 02-2311-7722#2386 | 2023-08-02 00:58:53
行政院環境保護署環保署書面之公共工程及採購契約
不定期更新,43許小姐 | (02)23117722#2483 | 2022-01-15 01:10:14
行政院環境保護署空氣品質小時值_臺南市_善化站
每1時更新,167陳先生 | 02-2311-7722#2386 | 2023-08-02 00:57:46
行政院環境保護署機動車輛測定機構許可項目資料
每1月更新,123楊先生 | (03)491-5818轉2103 | 2023-07-27 01:01:42
行政院環境保護署歷年土壤調查_環保署土壤重金屬含量調查(25公頃)
不定期更新更新,114謝小姐 | (02)23832389*8302 | 2022-01-14 01:20:17
行政院環境保護署
固定污染源設備元件揮發性有機物洩漏檢測申報資料
每3月更新,253戴先生 | 02-2311-7722#6208 | 2023-08-07 01:02:40
行政院環境保護署開發單位公開說明會訊息公聽會訊息
每2月更新,135黃先生 | 02-23117722#2748 | 2023-08-06 01:04:33
行政院環境保護署空氣品質小時值_桃園市_觀音站
每小時更新更新,180謝小姐 | 02-2311-7722#2386 | 2022-01-14 01:03:49
行政院環境保護署環保旅店旅館資訊
每1月更新,152林先生 | 02-23117722#2926 | 2023-07-27 01:02:28
行政院環境保護署特殊性工業區品保品管後監測值資料檔(一般空氣污染物)
每年更新更新,139丁小姐 | 02-2371-2121#6101 | 2022-01-15 01:06:51
行政院環境保護署
建檔公廁明細-桃園市
不定期更新更新,180曾小姐 | (02)2311-7722#2760,(02)2311-7722#2894 | 2022-01-15 01:14:45
行政院環境保護署建檔公廁明細-新竹市
不定期更新更新,187曾小姐 | (02)2311-7722#2760,(02)2311-7722#2894 | 2022-01-15 01:15:00
行政院環境保護署管制事業下水道系統環工技師專責人員證號資料資訊平台
不定期更新更新,60葉先生 | 02-2311-7722#2821 | 2023-08-09 01:05:18
行政院環境保護署地下水污染管制區
不定期更新更新,39賴小姐 | 02-2383-2389#8102 | 2022-01-15 01:16:39
行政院環境保護署毒化物運作紀錄申報總量
每6月更新,160許先生 | 02-23257399#55328 | 2023-07-27 01:03:31
行政院環境保護署
PM2.5日均值(每日提供)
每1日更新,83陳先生 | 02-2311-7722#2386 | 2023-08-08 00:58:45
行政院環境保護署公民營製造業、用水、電力及燃氣供應業污染防治支出
每1年更新,48顏先生 | 02-23117722#2109 | 2023-07-30 01:00:38
行政院環境保護署行政院環境保護署環境檢驗所會計月報
每1月更新,42鍾小姐 | 03-4915818#3004 | 2023-08-09 01:05:46
行政院環境保護署點源網格空氣污染排放量(TWD97)
每2年更新,776劉小姐 | 02-23117722#6111 | 2023-07-30 01:04:45
行政院環境保護署環保署考核直轄市及縣(市)政府環境保護績效作業要點
不定期更新更新,38陳先生 | (02)2311-7722分機2971 | 2023-08-07 01:03:24
行政院環境保護署
歷年環保署農地_全國重金屬污染潛勢之管制及調查計畫
不定期更新更新,97謝先生 | (02)23832389*8302 | 2022-01-14 01:20:23
行政院環境保護署柴油新車審驗資料-合格證明
不定期更新更新,39李小姐 | 02-2311-7722#6311 | 2023-08-09 01:04:48
行政院環境保護署公民營廢棄物清除機構資料
每月更新更新,152何先生 | 02-2311-7722#2653 | 2022-01-14 01:26:25
行政院環境保護署縣市(連江縣)小時值-每小時
每小時更新更新,81謝小姐 | 02-2311-7722#2386 | 2022-01-15 01:02:40
行政院環境保護署環境噪音監測站位置圖
不定期更新更新,50林先生 | 02-23712121#6403 | 2022-01-15 01:16:29
行政院環境保護署